Engineering guide
Prepackaged Magnesium Anodes: Backfill and Installation
Buried magnesium and zinc anodes work inside a backfill, not in bare soil. ISO 15589-1:2015 sets out what the backfill is for, its typical composition, how prepackaged anodes are prepared and placed, and what to measure at start-up.
Backfill
What the backfill does
For galvanic anodes, ISO 15589-1 allows only electrolytic-conduction backfills, normally a mixture of gypsum, bentonite clay and sodium sulfate. The required composition belongs in the anode specification (ISO 15589-1:2015, 10.6).
The backfill lowers the local resistivity around the anode and prevents insulating corrosion products from building up on the anode surface (10.6). A typical mix is:
- 75 % gypsum
- 20 % bentonitic clay — for water retention
- 5 % sodium sulfate — to improve the local conductivity
Source: ISO 15589-1:2015, 10.6. Gypsum also helps to minimise anodic polarisation, mainly for zinc anodes (10.6 Note).
When installed in soil for pipelines, magnesium anodes should be used with backfill; zinc anodes shall be, except where the soil contains chlorides or sulphates (10.3, 10.4).
Preparation
Before burial
A prepackaged anode is supplied with its dry backfill in a porous sack. ISO 15589-1 requires such packages to be immersed in a muddy mixture of soil and water to dampen the backfill before burial (ISO 15589-1:2015, 10.8).
Galvanic anodes should not be buried directly in the soil but in a backfill (10.8).
Placement
Where to place the anodes
- Bury the anodes 3 m to 5 m from the pipeline, at pipeline depth or lower, to reach wet electrolyte with better resistivity (ISO 15589-1:2015, 10.8).
- Several anodes may be connected at one location to deliver the total current; for long pipeline sections or non-homogeneous soil they may be spread along the pipeline for better current distribution (10.5).
- Even with backfill, magnesium anodes should not be used above a soil resistivity of 100 Ω·m (10,000 Ω·cm) unless an engineering evaluation or field tests confirm the design (10.4).
Connection
Cable connection and test stations
- Connect the anode cables to the pipeline in an accessible facility, so that potential and current can be measured. Permanent high-resistance measuring shunts should not be installed in the anode circuit, because they reduce the current (ISO 15589-1:2015, 10.7).
- Test stations should be installed at intervals of not more than 3 km in rural areas and 1 km in urban or industrial areas, and at features such as isolating joints, metallic casings and bonds to other pipelines (11.2).
Start-up
Start-up measurements
- Before connection — include the anode-to-electrolyte potential of the galvanic anodes in the preliminary potential measurements (ISO 15589-1:2015, 12.2).
- Connect and confirm — after connecting all anodes as defined in the design, confirm they function correctly; where necessary, connect them through variable resistors to limit the current (12.3.2).
- Measure every anode — the protective current output of each galvanic anode and the pipeline ON-potential at the anode locations (12.3.2).
- Adjust and repeat — if the results raise doubt about the effectiveness of the protection, adjust any resistors and measure again (12.3.2).
- Document — the commissioning report contains the measurement results, any changes to the design and information useful for future monitoring (12.1).
Documents
Marking and documents to ask for
- Galvanic anodes should be marked with the type of material, for example trade name, anode mass without backfill and cast number (ISO 15589-1:2015, 10.2).
- Full documentation of the number, types, mass, dimensions, chemical analysis and performance data of the anodes shall be provided (10.2).
- The environmental impact of the anodes and their backfill shall be considered (10.2).
Questions
Short answers
- What is the standard backfill for magnesium anodes?
- ISO 15589-1:2015 gives a typical mix of 75 % gypsum, 20 % bentonitic clay and 5 % sodium sulfate for zinc and magnesium anodes; the composition required for a project belongs in the anode specification.
- Do prepackaged anodes need to be soaked before burial?
- Yes. ISO 15589-1:2015 requires anodes packaged in a porous sack of dry backfill to be immersed in a muddy mixture of soil and water to dampen the backfill before burial.
- How far from the pipeline should magnesium anodes be installed?
- ISO 15589-1:2015 recommends 3 m to 5 m from the pipeline, at pipeline depth or lower, to reach wet soil with better resistivity.
Sources
Standards used in this guide
- ISO 15589-1:2015 Cathodic protection of pipeline systems — Part 1: On-land pipelines. Clauses 10.2 to 10.8, 11.2, 12.1, 12.2 and 12.3.2.
Values are quoted from the editions listed. Where a project specification, purchase order or CP design states other values, those govern.