Cathodic Protection of Storage Tank Bottoms: Systems, Liners and Monitoring

The soil side of an on-grade steel tank bottom cannot be inspected while the tank is in service, so its cathodic protection has to be planned with the foundation. This guide summarizes NACE RP0193-2001 for external tank-bottom CP: when galvanic or impressed current anodes are used, why a liner or a second bottom changes where the anodes go, and how reference electrodes and test stations are arranged so the whole bottom can be monitored.

NACE RP0193-2001 Sections 5 to 11 Edition stated with every value
Concept view of an MMO titanium ribbon anode grid beneath a storage tank bottom
Product concept visualization; the grid layout follows the tank CP design.

Quick answer

What a tank-bottom CP system has to do

NACE RP0193-2001 lists the objectives of the design: protect the tank bottom from soil-side corrosion; provide sufficient, uniformly distributed current; give a design life matching the tank bottom or allow periodic anode replacement; minimize interference currents; allow for changes in current requirement; place components where damage is unlikely; and provide monitoring facilities to check performance (NACE RP0193-2001, 5.2.1).

Galvanic anodesImpressed current
No external power requiredExternal power required
Fixed, limited driving voltageDriving voltage can be varied
Limited currentCurrent can be varied
Satisfies small current requirementsSatisfies high current requirements
Used in lower-resistivity environmentsUsed in higher-resistivity environments
Usually no stray current interferenceMust consider interference with other structures

Source: NACE RP0193-2001, Table 1.

Impressed current is usually chosen when the service temperature is elevated, when higher current densities or driving potentials are needed in high-resistance electrolytes, or when it is the more economical system for the project (5.2.2).

Impressed current

Impressed current anodes around, under or deep below the tank

  • The positive terminal of the d.c. source is connected through insulated cables to the anodes and the negative terminal to the tank bottom. Anode systems can be shallow groundbeds around or under the tank and/or deep anode groundbeds. (NACE RP0193-2001, 5.2.3, 6.2.1)
  • Groundbeds may be vertical, angled, deep or horizontal, and anodes may be distributed under the tank bottom. The choice depends on the environment, current requirement, size and type of the bottom, new or existing construction, and single or double bottom. Deep anode systems are designed and installed in accordance with NACE RP0572. (6.2.2, 6.2.3)
  • Anode materials listed include mixed-metal oxides, polymer carbon, graphite, high-silicon chromium-bearing cast iron, platinized niobium and platinized titanium, scrap metal and cleaned below-grade structures. Platinized niobium and polymeric anodes should not be used in hydrocarbon-contaminated environments. (5.2.3.1, 6.2.4 Note)
  • Coke backfill, metallurgical coal coke or calcined petroleum coke, lengthens anode life, but coke is noble to carbon steel and should not touch the tank bottom. (6.2.5)
  • In a distributed-anode system, voltage and current attenuate along the anode and the header cable, so anode length, size, spacing and cable size are optimized together. Where gas could be trapped at the anodes, venting is provided. Cable insulation should be resistant to oil and water. (6.2.6, 6.2.7, 6.2.1)

Groundbed types are compared in more detail in the deep-well vs shallow groundbed guide.

Galvanic anodes

When magnesium or zinc anodes are enough

  • Galvanic protection may be applied where a dielectric coating minimizes the exposed steel, where the tank is small, or where no power source is available. For uncoated or large bottoms, impressed current should be considered to minimize cost. (NACE RP0193-2001, 7.2, 7.2.2)
  • Galvanic anodes are connected to the tank bottom through a test station so that anode performance and voltage drops can be monitored. (7.2.1)
  • The three most common anodes in soil are standard magnesium, high-potential magnesium and high-purity zinc, selected on current requirement, soil conditions, tank bottom temperature and cost. The current from each depends on soil conditions, anode shape (bar, block or ribbon) and driving potential. (7.3.1 to 7.3.3)
  • High-purity zinc should meet ASTM B418 Type II. Zinc should not be used where the anode environment is above 49 °C (120 °F), and carbonates, bicarbonates or nitrates in the electrolyte may affect its performance. (7.3.4, 7.3.5)
  • Galvanic anode backfill is most commonly a mixture of gypsum, bentonite and sodium sulfate. Anodes come with lead wire attached by the supplier, at least 2 mm in diameter (#12 AWG). (7.3.6, 7.3.7)

Liners and double bottoms

Why a liner or second bottom moves the anodes

Tank bottom with liner: anodes and reference electrode between liner and bottomtest stationtanklineranodereference electrodeboth placed between the liner and the tank bottom
Liner or double bottom. A non-conductive barrier blocks current from anodes outside it, so anodes and reference electrodes go between the barrier and the steel bottom (8.2.1, 8.2.2).
Existing single-bottom tank: anodes around the tank, access tube to the centrerectifiertankanodeanodeperforated access tubeto the centre of the bottomanodes around the tank(vertical, angled, deep or horizontal)
Existing single bottom, no liner. Anodes can stand around the tank; an access tube under the bottom lets potentials be measured at the centre (6.2.2, 9.4.2, 10.6.3).

Schematic sketches, not to scale.

  • Release-prevention barriers and secondary steel bottoms may shield the primary bottom from cathodic protection current. (NACE RP0193-2001, 8.1.2)
  • A non-conductive membrane or liner prevents current from anodes outside the barrier from reaching the tank. Anodes must be placed between the barrier and the carbon steel tank bottom. A conductive barrier, with anodes outside it, must keep its resistance low enough for sufficient current to flow. (8.2.1)
  • Stationary reference electrodes and/or portable electrode insertion tubes must be located between the tank bottom and the barrier, or between the bottoms. (8.2.2)
  • A replacement bottom installed over the original one, with electrolyte between them, can suffer galvanic corrosion; CP should be considered for the new bottom, with anodes and reference electrodes in the electrolyte between the two bottoms. A non-conductive liner above the original bottom reduces that galvanic activity and the current required. If the old bottom is removed, the design follows a standard single-bottom tank. (8.3.1 to 8.3.4)
  • Space between bottoms is limited, so close anode spacing may be needed for uniform current distribution. Impressed current anodes must not contact the steel, and the electrolyte must be compacted to prevent settlement of the new bottom. Either galvanic (magnesium or zinc) or impressed current anodes, including mixed-metal oxides, may be used. (8.4.1, 8.4.2, 8.4.4)

Distributed MMO anodes are one way to meet these limits; see the MMO titanium ribbon anode and zinc ribbon pages for supply details.

Installation and monitoring

Reference electrodes, test stations and surveys

Reference electrodes under every tank

  • Stationary reference electrodes, or non-conductive perforated tubes for a portable electrode, should be installed under all tanks, whatever the groundbed type and location. Stationary electrodes may be prepackaged in backfill or placed inside the perforated access pipe surrounded by backfill. (NACE RP0193-2001, 9.4.1, 9.4.1.1)
  • The access pipe needs contact with the electrolyte (holes, slits or an open end) and at least one end accessible from outside the shell. Portable electrodes are pushed in with a non-metallic rod such as small-diameter PVC pipe; water can be injected for contact, deionized for double bottoms and secondary containment. (9.4.1.2)
  • Potentials measured from grade are strongly influenced by the perimeter of the bottom, so the centre is measured with a stationary electrode or an access tube under the tank. (10.6.3, 4.2.3) For existing tanks, access piping is installed by guided horizontal drilling, keeping a constant distance from the bottom. (9.4.2, 9.4.2.1)

Anode installation and test stations

  • Anodes must not touch piping or tankage; lead wires need slack against settlement and are run away from the construction, then terminated in a test station or junction box, which may include shunts for measuring anode current. (9.3.1 to 9.3.3)
  • Test stations or junction boxes are mounted on or near the tank side away from vehicle traffic, allow the anodes to be disconnected for current and IR-drop measurements, and are clearly marked. In galvanic systems, calibrated shunts typically rated between 0.001 and 0.1 Ω measure anode output. (9.5.1 to 9.5.6)
  • Lead wires to the test station are protected by at least 46 cm (18 in) of cover and/or conduit, with warning tape over direct-buried cable. (9.5.7)

Surveys

  • Annual surveys verify the protection criteria, including the accuracy of stationary reference electrodes and the effectiveness of isolating fittings and continuity bonds; impressed current sources are checked at bimonthly intervals. (11.2.2, 11.2.3)
  • Minimum potential tests: four equally spaced points on the circumference plus the centre for tanks up to 18 m (60 ft) diameter; eight points plus the centre above 18 m. (11.2.4)

Checklist

What to send for a tank-bottom CP quotation

  1. Tank data — number of tanks, diameter, new or existing, single or double bottom, liner or secondary containment, product temperature.
  2. Foundation — pad and fill materials with their resistivity, ringwall details and the space available between bottoms.
  3. Design basis — system type, current requirement and design life from the CP design, and the owner specification with its edition.
  4. Anodes — MMO ribbon grid with any conductor bars, HSCI or MMO tubular anodes for perimeter or deep beds, or magnesium, zinc or zinc ribbon for galvanic systems, with lead lengths.
  5. Monitoring — stationary reference electrodes and their quantity, perforated access tube length, test stations or junction boxes with shunts.
  6. Cables and documents — oil- and water-resistant cable, splice kits, certificates required and destination port.

Questions

Short answers

Can galvanic anodes protect a large tank bottom?
NACE RP0193-2001 (7.2, 7.2.2) applies galvanic protection where a coating minimizes the exposed steel, where the tank is small or where no power is available. For uncoated or large bottoms it recommends considering impressed current to minimize cost.
Where do the anodes go if the tank has a liner?
A non-conductive liner blocks current from anodes outside it, so NACE RP0193-2001 (8.2.1, 8.2.2) requires the anodes, and the reference electrodes or insertion tubes, to be placed between the barrier and the carbon steel tank bottom.
Why install a reference electrode under the tank?
Potentials measured from grade are dominated by the perimeter of the bottom. NACE RP0193-2001 (9.4.1, 10.6.3) calls for stationary reference electrodes or perforated access tubes under all tanks so the centre of the bottom can be measured.
Can zinc anodes be used under hot tanks?
NACE RP0193-2001 (7.3.5) says zinc anodes should not be used where the temperature of the anode environment is above 49 degC (120 degF), because higher temperatures can passivate the anode.

Sources

Standards used in this guide

  • NACE RP0193-2001 External Cathodic Protection of On-Grade Carbon Steel Storage Tank Bottoms. Paragraphs 4.2.3, 5.2.1 to 5.2.3.1, Table 1, 6.2.1 to 6.2.7, 7.2 to 7.3.7, 8.1.2 to 8.4.4, 9.3.1 to 9.5.7, 10.6.3 and 11.2.2 to 11.2.4.
  • Named but not quoted: NACE RP0572 for deep anode groundbeds and ASTM B418 for zinc anodes, both referred to by RP0193.

Paragraph numbers and values are from the 2001 edition; the standard was later revised and reissued as SP0193. Use the edition named in your project specification, and where it or the CP design states other values, those govern.

Factory supply & quotation

Under-Tank MMO Ribbon Grids, Linear Anodes & Permanent Monitoring

CathPro supplies MMO-coated titanium ribbon, titanium conductor bars, spot-welded grid accessories, prepackaged linear anodes, ASTM B418 zinc ribbon, long-life under-tank Cu/CuSO4 and zinc reference electrodes, perforated monitoring tubes and junction boxes for new-build and double-bottom storage tanks.