Pipeline route, station layout or tank plan, anode length and separation from the protected steel and other buried services.
MMO/Ti linear anode | Pre-packaged in coke | Station, pipeline and tank-bottom ICCP
MMO/Ti Flexible Linear Anode
A continuous impressed-current anode laid close to the protected steel: MMO-coated titanium wire joined to an internal copper cable at sealed nodes, packed in calcined petroleum coke inside a fabric jacket and braided mesh. Send the route, current demand, soil data and design life for an order-specific offer.
- ASTM B863 Titanium Wire
- IrO₂–Ta₂O₅ or RuO₂–IrO₂ Coating
- NACE TM0108 / ISO 19097-2 Life Testing
- Breakpoint-Locatable Option
Illustrations are schematic and not to scale. Final wire diameter, cable, coating, rated output, design life, reel lengths and inspection scope are controlled by the confirmed quotation and order documents.

Required current per metre and design life select the wire diameter from the rating table.
Resistivity, chlorides, groundwater, temperature and termite risk select the coating and cable sheath.
The complete current path
A continuous anode beside the structure it protects.
The MMO-coated titanium wire is the current-discharge element. The internal copper cable carries the current along the run with little voltage drop and feeds the wire at sealed nodes; the coke column passes the current to the soil, which carries it to the protected steel.
Because the anode runs parallel and close to the structure, the current is distributed along its whole length instead of leaving one remote groundbed — suited to dense buried piping, earthing systems and interference-sensitive sites.

Working principle: the power supply drives current from the anode through coke and soil to the pipeline. Schematic, not to scale.
Rated output and design life
Select the wire diameter from current per metre and design life.
The rated output is the maximum continuous current per metre of anode for the stated design life. It must not be confused with the much higher current used in short-term tests.
Current per metre
Required current ÷ installed anode length
The CP design sets the total current; the run length, segment layout and feed points set the duty per metre.
Wire diameter
Rating table: 1.0, 1.5 or 2.0 mm
Choose the wire whose rating at the required design life covers the duty per metre, with the project's design margins.
Life evidence
Accelerated life test of the MMO/Ti wire
Design life is verified by accelerated life testing to NACE TM0108 or ISO 19097-2.
| MMO/Ti wire | 25 years | 30 years | 40 years | 50 years |
|---|---|---|---|---|
| 1.0 mm | 52 mA/m | 43 mA/m | 33 mA/m | 26 mA/m |
| 1.5 mm | 78 mA/m | 65 mA/m | 49 mA/m | 39 mA/m |
| 2.0 mm | 104 mA/m | 87 mA/m | 65 mA/m | 52 mA/m |
Ratings for IrO₂–Ta₂O₅ (α) coated wire; β coating and 0.8 mm wire on request. Project values are confirmed against the agreed design basis in the quotation.
Six components, one factory-made anode
What is inside the braided jacket.
The anode arrives ready to lay: no separate coke backfill, and no wire-to-cable connection other than the sealed factory nodes.
1 · MMO/Ti wire
Titanium wire to ASTM B863, Grade 1 (Grade 2 on request), 0.8–2.0 mm, coated with IrO₂–Ta₂O₅ (α) or RuO₂–IrO₂ (β), coating loading ≥ 6 g/m².
2 · Internal copper cable
Continuous single-core cable, 10, 16 or 25 mm², stranded class 2 copper to IEC 60228, rated 0.6/1 kV, e.g. PVDF/HMWPE dual insulation; sheath selected for the soil.
3 · Coke breeze
Calcined petroleum coke packed around wire and cable; lowers the anode-to-earth resistance and evens out the current discharge.
4 · Fabric jacket
Permeable, rot-resistant fabric holding the coke: burst ≥ 500 N, puncture ≥ 280 N, Martindale abrasion ≥ 100 cycles.
5 · Braided mesh
Polyester monofilament braid, coverage ≥ 60 %, protecting the jacket during handling and laying.
6 · Nodes
Factory wire-to-copper connections at ≤ 5 m intervals, contact resistance ≤ 0.0009 Ω, sealed to IPX8 (IEC 60529).

Coating, sheath and type
Match the anode to the soil, the temperature and the risk of damage.
Model codes give type, wire diameter, cable size and coating — for example FA-1016α: standard type, 1.0 mm wire, 16 mm² cable, IrO₂–Ta₂O₅ coating. FApro is the breakpoint-locatable type.
| Condition | Recommendation |
|---|---|
| Non-saline soil | α coating (IrO₂–Ta₂O₅); cable sheath HDPE or HMWPE |
| Saline or alkaline soil | β coating (RuO₂–IrO₂); fluoropolymer-insulated cable with HDPE sheath, or XLPE sheath |
| Groundwater above anode depth | Low-permeability sheath, preferably PE |
| Service temperature below −15 °C | XLPE, PE or cold-resistant rubber sheath; avoid PVC |
| Service temperature above 60 °C | Heat-resistant PVC, XLPE or EPR sheath |
| Severe termite risk | Hard, termite-resistant outer sheath |
| Risk of third-party damage | Breakpoint-locatable type FApro: a break in the buried anode can be located with an anode fault locator (in-line joints only, no tee joints) |
Installation guidelines
Lay it slack, keep the separation, never drag it.
Check model, length, continuity and certificates on receipt. Handle reels by forklift from the flange sides only, and repair any jacket damage before laying.
- Parallel to the pipeline, ≥ 300 mm and ≥ half the pipe diameter away, level with the pipe bottom
- No contact with buried metal; insulating sleeve where it crosses pipes, earth electrodes or other anodes
- Keep the anode slack; allow 2–5 % extra length
- Corner radius ≥ 16 × anode outer diameter
- Station areas: segments ≤ 300 m, each with its own cathode return
- Tank bottoms: ≥ 50 mm sand below the anode, no vibratory compaction
- Slopes of 20°–50°: fix every 15 m (≤ 30°) or 10 m (> 30°)
- Armoured cable: earth the armour at both ends during installation
- Backfill with sieved soil
- Below the sheath's minimum laying temperature, pre-warm reels to about 25 °C and lay within 2 h

Standards by scope
Use each reference only for the layer it controls.
There is no ISO or IEC product standard for linear MMO anodes. CathPro data sheet CP-DS-FA-001 is the product specification; the references below control materials, tests and system design.
| Reference | What it controls | Correct application |
|---|---|---|
| ISO 15589-1 | Cathodic protection of on-land pipeline systems. | System design, criteria and commissioning by the project engineer; not an anode product specification. |
| ISO 19097-2:2018 | Accelerated life testing of MMO anodes for soils and natural waters. | Qualification of the MMO/Ti wire under declared conditions; not a field-life guarantee for every installation. |
| NACE TM0108 | Testing of catalyzed titanium anodes for use in soils or natural waters. | Accelerated life test of the MMO/Ti wire supporting the rating table. |
| ASTM B568 · ISO 3497 | Coating thickness by X-ray spectrometry. | Coating loading of the MMO/Ti wire (≥ 6 g/m²). |
| ASTM B863 | Titanium and titanium-alloy wire. | Substrate wire grade and properties; it does not cover the MMO coating or the finished anode. |
| IEC 60529 · IEC 60228 | IP code · conductors of insulated cables. | IPX8 sealing test of the nodes · copper conductor class of the internal cable. |
| API RP 651 · AMPP SP0193 | Cathodic protection of above-ground storage-tank bottoms. | Tank-bottom application and design references; not product certification. |
Product specification
Technical data of the standard product.
Values from data sheet CP-DS-FA-001. The accepted quotation, approved data sheet and project ITP govern each order.
| Parameter | Requirement |
|---|---|
| Outer diameter | 38 ± 2 mm |
| Linear mass | > 1.30 kg/m |
| MMO/Ti wire | ASTM B863 Grade 1 (Grade 2 on request); 0.8, 1.0, 1.5 or 2.0 mm; coating ≥ 6 g/m² (XRF, ASTM B568 or ISO 3497); max. 100 A/m² of wire surface in coke backfill |
| Internal cable | 10, 16 or 25 mm² stranded copper (IEC 60228, class 2), 0.6/1 kV, e.g. PVDF/HMWPE dual insulation |
| Minimum bending radius | ≤ 150 mm with 10 mm² cable; larger cables per supply data sheet |
| Nodes | ≤ 5 m apart (position ± 10 %); contact resistance ≤ 0.0009 Ω; IPX8 to IEC 60529 (≥ 0.1 MPa, ≥ 60 min) |
| Coke breeze | Calcined petroleum coke; fixed carbon ≥ 90 %; 98 % < 1.27 mm and 80 % > 0.254 mm; resistivity ≤ 0.06 Ω·cm |
| Working performance (type test) | 15 days in 3 % NaCl at 100 A/m² of wire surface: output maintained, supply voltage within ± 10 %, nodes intact and dry |
| Joints | Whole reels: max. 2 per 400 m; cut lengths: none below 100 m, max. 1 for 100–400 m; ≤ 0.01 Ω across a joint |
| Reels | Typical 500 m (approx. 1.4 × 1.1 × 1.5 m, 720 kg gross) or 700 m (approx. 1.6 × 1.1 × 1.7 m, 990 kg gross); other lengths on request |
Inspection and documents
Agree the evidence before manufacture.
Records are included as confirmed in the quotation and the project document register.
Every reel
Appearance, outer diameter, linear mass and electrical continuity.
Every lot
Accelerated life test report of the MMO/Ti wire (NACE TM0108 or ISO 19097-2).
Orders of 5000 m or more
Three sampled reels: node resistance, IPX8 sealing, braid coverage, bending and 15-day working test.
Type tests
All product requirements, repeated yearly and after design, material or process changes.
Release documents
Certificate of conformity, inspection certificate (EN 10204 3.1 on request), reel length list and packing list.
Witness inspection
Customer or third-party witness points by agreement, stated in the order.
Download the MMO/Ti Flexible Linear Anode Data Sheet
Data sheet CP-DS-FA-001: construction, ratings, technical data, selection, installation, inspection and ordering information. No form is required.
Technical questions
Turn a length-and-price request into a quoteable anode requirement.
These answers separate the anode product from the CP system design, the installation and the project documents.
Is an MMO/Ti flexible anode the same as a conductive polymer anode?
No. The MMO/Ti flexible anode discharges current from MMO-coated titanium wire that is connected to the internal copper cable at factory nodes. A conductive polymer anode uses carbon-loaded polymer extruded over a copper conductor and has no nodes. Ratings, design life and acceptance basis differ.
How is the MMO/Ti wire diameter selected?
From the required current per metre of anode and the design life, using the rating table. For example, 52 mA/m for 25 years needs 1.0 mm wire; the same duty for 50 years needs 2.0 mm wire.
Can the anode be cut and joined on site?
Order factory lengths where possible. Whole reels contain at most two joints per 400 m; cut lengths shorter than 100 m have no joint and lengths of 100–400 m at most one. The resistance across a joint must not exceed 0.01 Ω, using the matching joint kits.
What is the breakpoint-locatable type FApro?
FApro is built so that a break in the buried anode can be located from the surface with an anode fault locator. It uses in-line joints only, without tee joints, so that the locating signal is not disturbed.
Which standard covers this product?
There is no ISO or IEC product standard for linear MMO anodes. CathPro data sheet CP-DS-FA-001 is the product specification. Tests refer to ASTM B863, ASTM B568, NACE TM0108 or ISO 19097-2, IEC 60228 and IEC 60529, and the CP system is designed to ISO 15589-1 or the project specification.
What information is needed for quotation?
Provide the route, station layout or tank plan and anode length, required current and design life, soil resistivity and chemistry, groundwater level, service temperature, termite risk, preferred model, reel lengths and accessories, governing specification, quantity, destination and required inspection documents.
Technical RFQ
Send the inputs that set the anode duty.
Have a CP design, route drawing or owner specification? Send it. Still in design? Send the available route, current and soil data; we will identify the missing inputs.
- We check application fit and RFQ completeness.
- We propose wire diameter, coating, cable and reel lengths against the rating table.
- We confirm accessories, inspection scope and documents before quotation.